Calibrations

What is "NIST Traceability"?

International Light obtains fully characterized Primary Standard Detectors directly from the National Institute of Standards and Technology (NIST), a division of the United States Department of Commerce. Through the transfer of standards technique, we compare the output of a customer's detector to a standard under tightly controlled laboratory conditions. The calibration factor is computed and programmed, allowing direct readings in the optical units requested.

 Spectroradiometric responsivity scans and spectrophotometric transmission scans are available, as well as calibration of custom equipment. Our Optical Calibration Lab adheres to the provisions of ANSI.Z540-1 & ISO.10012-1. Extra charges apply for audited military calibrations, and must include electrical recalibration (ECAL) of the radiometer, which is then used in the optical calibration of any detectors used in the system.

 

Standard Calibrations:

 
Item

 

Calibration Description

 

BIR  Band Irradiance Response: Spectral irradiance response (amps*cm2*nm/watt) over the bandwidth of an ILsensor assembly.

 

CSAR  Custom Scanned Absolute Response: Plot of irradiance response vs. wavelength for other than IL sensor assemblies.

 

CSIM  Custom Spectral Irradiance Measurement: Plot of absolute irradiance (watts/cm2) vs. wavelength (nm) for any light source.

 

CSTM  Custom Spectral Transmission Measurement: Plot of absolute transmission vs. wavelength (nm) for any filter or optical material.

 

ECAL  Electrical Calibration of IL Radiometer: Electrical check and/or adjustment of accuracy to NIST Standards, check linearity and I/O over entire range.

 

IBIR  Internal Band Irradiance Response: Band irradiance response of an IL sensor assembly for readout in W/cm2/nm for IL1400A detectors.

 

IER  Internal Recalibration of IL390C or IL290A Light Bug: Electrical and optical calibration in mJ/cm2, including battery replacement.

 

IPIR  Internal Peak Irradiance Response: Irradiance response at peak sensitivity of IL1400A detectors for direct readout in W/cm2.

 

IPPR  Internal Peak Power Response: Power response at peak sensitivity of an IL sensor assembly for direct readout in Watts for IL1400A detectors.

 

IYIS  Internal Photopic Illuminance Response: Illuminance sensitivity of an IL sensor assembly for direct readout in foot-candles or lux for IL1400A detectors.

 

PINR  Peak Intensity Response: Intensity response (amps*sr/W) at peak sensitivity of an IL sensor assembly.

 

PIR  Peak Irradiance Response: Irradiance response (amps*cm2/W) at peak sensitivity of an IL sensor assembly.

 

PIRE  Peak Irradiance Response - Einsteins (moles): Irradiance response (amps*cm2*sec/Einstein) at peak sensitivity of an IL sensor assembly.

 

PPR  Peak Power Response: Power response (amps/W) at peak sensitivity of an IL sensor assembly.

 

PRR  Peak Radiance Response: Radiance response (amps*cm2*sr/W) at peak sensitivity of an IL sensor assembly.

 

SAP  Scanned Absolute Power Response: Plot of absolute power response (Watts) vs. wavelength (nm) over the spectral band of an IL sensor assembly.

 

SAR  Scanned Absolute Response: Plot of irradiance response (amps*cm2/Watt) vs. wavelength (nm) over the spectral bandwidth of an IL detector.

 

SIR  Spectral Irradiance Response: Spectral irradiance response (amps*cm2*nm/Watt) over the entire spectral bandwidth of an IL Spectroradiometer.

 

SOL  Solar UVB Response: Irradiance response as compared to simulated solar UVB spectral irradiance integrated below 315 nm

 

SRR  Scanned Relative Response: Plot of relative response (% of peak) vs. wavelength (nm) over the spectral bandwidth of an IL sensor assembly.

 

XIR  Irradiance Response at Wavelength X: Irradiance response (amps*cm2/Watt) at specified wavelength, X, of an IL sensor assembly.

 

XPR  Power Response at Wavelength X: Power response (amps/Watt) at specified wavelength, X, within the spectral bandwidth of an IL sensor assembly.

 

YFS  Photopic Flux Sensitivity: Total photopic flux (amps/lumen) sensitivity of an IL detector with integrating sphere input optics.

 

YIN  Standard Lamp Intensity: Mean spherical candlepower output of lamp used with INS250 Integrating Sphere.

 

YINS  Photopic Intensity Sensitivity: Photopic intensity response (amps/candela) of an IL sensor assembly.

 

YIS  Photometric Illuminance Sensitivity: Illuminance sensitivity (amps*ft2/lm, amps*m2/lm) of an IL sensor assembly.

 

YLS  Photometric Luminance Sensitivity: Luminance sensitivity (amps/fL) of an IL sensor assembly.

 

 
  