Meter: IL1700 Research Radiometer
Detector: SED033/UVA/W
Dynamic Range: 1.25 x 10-10 to 0.25 W/cm2
Spectral Range: 315 to 390 nm (10 %)
Meter: IL1400A Radiometer / PhotometerThe IL1402 and IL1702 UVA Phototherapy Radiometer systems are designed for fast and accurate irradiance measurement covering a wide dynamic range, for measuring UVA lamps commonly used in phototherapy apparatus, such as UV booths and hand & foot units. The IL1702 or IL1402 can be used as an independently calibrated second party check on the meter built into an exposure system, or to monitor lamp degradation. The useful dose integration capability (with full integration autoranging) provides the most accurate measure of a typical UV exposure. The lamp output must be accurately known in order to maximize drug effectiveness while maintaining patient safety.
Detector: SEL033/UVA/TD
Dynamic Range: 20 nW/cm2 to 70 mW/cm2
Spectral Range: 315 to 390 nm (10 %)
Meter: IL1700 Research Radiometer
Detector: SED240/UVB-1/W
Dynamic Range: 1 x 10-8 to 1 x 10-2 W/cm2
Spectral Range: 265 to 332 nm (10 %)
Meter: IL1400A Radiometer / PhotometerThe IL1403 and IL1703 UVB Phototherapy Radiometer systems measure UVB light, which can cause serious eye and skin damage in excessive doses. The solar-blind detector is blind to the visible and long wavelength output of most lamps, measuring only the UVB portion. The standard system has been designed with a broad spectral response, for measuring standard UVB lamps or even TL series lamps.
Detector: SEL240/UVB-1/TD
Dynamic Range: 20 µW/cm2 to 150 mW/cm2
Spectral Range: 265 to 332 nm (10 %)
We also offer an optional UVB detector (SED240/UVB/W) that distinctly separates UVA from UVB at 315 nm, for research oriented applications or those requiring a narrower bandwidth. A TLS312 filter and XIR single wavelength calibration is available for TL series lamps at 311 nm.
Meter: IL1700 Research Radiometer
Detector: SED033/BR/W
Dynamic Range: 6 x 10-10 to 1 W/cm2
Spectral Range: 410 to 485 nm (10 %)
Meter: IL1400A Radiometer / PhotometerThe IL1404 and IL1704 Bilirubin Phototherapy Radiometer systems are designed to monitor lamp output in neo-natal hyperbilirubinemia exposure chambers, with detectors designed to exactly match the photo-oxidation response of Bilirubin in the blood of Jaundice patients. The standard detectors have a narrow spectral response from 431 to 472 nm.
Detector: SCL144
Dynamic Range: 100 nW/cm2 to 500 mW/cm2
Spectral Range: 422 to 488 nm (10 %)
We also offer Wide Range Bilirubin probes, the SED033/BR-1/W and SCL145, which cover a broader spectral range (360 to 525 nm). Custom input optics are available for fiber optic blanket delivery systems or any non-standard application.